PRODUCT / SPLIT SYSTEM

Split Charging System

Explore product views and specifications, then discuss export supply and OEM / ODM configuration.

Split charging system
720 kW~1 MW+

Cabinet · Standard / liquid-cooled terminals

F6 / F19 cabinets cover 720 kW~1 MW+, paired with air-cooled or liquid-cooled terminals. Review the listed configuration ratings, then discuss export configuration and customization.

FEATURES / CONFIGURATION

A closer look at the equipment.

01

Two cabinet families

F6 offers 720 / 800 / 960 kW; F19 offers 1280 / 1600 / 1920 kW. These are cabinet total-power ratings.

02

Air-cooled and liquid-cooled terminals

Air-cooled terminal current is 0–250 A / 0–300 A per connector; the liquid-cooled terminal supports 0–600 A per connector. Terminal power and per-connector current are specified separately.

03

Separate cabinet and terminals

The cabinet provides an internal service-display interface. Terminals have a 7-inch colour touchscreen with QR, VIN and card activation.

SELECTION / CONFIGURATION

Define your equipment configuration.

Cabinet models and total power
F6: 720 / 800 / 960 kW; F19: 1280 / 1600 / 1920 kW
Air-cooled terminal
F/ZD250 / F/ZD300 · Dual connectors · 5 m cable
Liquid-cooled terminal
F/ZD600 · Dual connectors · 5 m cable
System power configuration
Cabinet total power, terminal rating and per-connector current are selected separately

Images illustrate enclosure options. Model, dimensions, connector and performance specifications are confirmed for the agreed configuration.

TECHNICAL SPECIFICATIONS

Technical specifications

View the configuration, then expand performance, protection and operating conditions.

Cabinet ratings are total cabinet power. Terminal output ratings are not per-connector ratings. Actual output depends on cabinet allocation, vehicle demand and system configuration.

F6 · Power cabinet720 / 800 / 960 kW
Configuration and installation6 items
ModelF6
Power options720 / 800 / 960 kW
ConnectorsConfigured for the project (customized within the specified limits)
InstallationFloor mounting; cabinet and terminals installed separately
Enclosure materialGalvanized enclosure
Dimensions1960 × 1700 × 1200 mm (source order; length / width / height order to be confirmed)
Interaction and communication3 items
DisplayNo external display; internal commissioning display interface provided
Communication interfaceCAN
BMS auxiliary supply12 V / 24 V compatible
Electrical performance9 items
Input voltageAC 380 V ±15%
Supply frequency50 Hz ±5 (tolerance unit to be confirmed)
Charging voltage range150–1000 VDC
Charging current range250 A / 300 A / 600 A options
Input power factor≥0.99
Charging efficiency≥96.5% (peak charging efficiency)
Harmonic current≤5%
Current regulation accuracy≤±1%
Voltage regulation accuracy≤±0.5%
Protection10 items
Input overvoltage protectionNo output after protection; recoverable
Input undervoltage protectionNo output after protection; recoverable
Input overcurrent protectionNo output after protection; manual reset required
Input phase-loss protectionNo output after protection; recoverable
Output overvoltage protectionNo output after protection; recoverable
Communication fault protectionNo output after protection; recoverable
Short-circuit protectionNo output after protection; manual reset required
Emergency-stop protectionNo output after protection; manual reset required
Overtemperature protectionNo output after protection; recoverable
Lightning protectionNo output after protection; manual reset required
Environmental conditions4 items
Operating temperature−25 to 50 °C (normal operation)
Relative humidity0–95% (no frost)
Altitude≤2000 m
Storage temperature−45 to 75 °C
F19 · Power cabinet1280 / 1600 / 1920 kW
Configuration and installation6 items
ModelF19
Power options1280 / 1600 / 1920 kW
ConnectorsConfigured for the project (customized within the specified limits)
InstallationFloor mounting; cabinet and terminals installed separately
Enclosure materialGalvanized enclosure
Dimensions1960 × 2100 × 1200 mm (source order; length / width / height order to be confirmed)
Interaction and communication3 items
DisplayNo external display; internal commissioning display interface provided
Communication interfaceCAN
BMS auxiliary supply12 V / 24 V compatible
Electrical performance9 items
Input voltageAC 380 V ±15%
Supply frequency50 Hz ±5 (tolerance unit to be confirmed)
Charging voltage range150–1000 VDC
Charging current range250 A / 300 A / 600 A options
Input power factor≥0.99
Charging efficiency≥96.5% (peak charging efficiency)
Harmonic current≤5%
Current regulation accuracy≤±1%
Voltage regulation accuracy≤±0.5%
Protection10 items
Input overvoltage protectionNo output after protection; recoverable
Input undervoltage protectionNo output after protection; recoverable
Input overcurrent protectionNo output after protection; manual reset required
Input phase-loss protectionNo output after protection; recoverable
Output overvoltage protectionNo output after protection; recoverable
Communication fault protectionNo output after protection; recoverable
Short-circuit protectionNo output after protection; manual reset required
Emergency-stop protectionNo output after protection; manual reset required
Overtemperature protectionNo output after protection; recoverable
Lightning protectionNo output after protection; manual reset required
Environmental conditions4 items
Operating temperature−25 to 50 °C (normal operation)
Relative humidity0–95% (no frost)
Altitude≤2000 m
Storage temperature−45 to 75 °C
Air-cooled terminal250 / 300 kW
Configuration and installation7 items
ModelF/ZD250 / F/ZD300
Power options250 / 300 kW
ConnectorsDual connector
Charging cable length5 m
InstallationFloor mounting; power cabinet and terminals installed separately
Enclosure materialGalvanized enclosure
Dimensions1431 × 616 × 325 mm (source order; length / width / height order to be confirmed)
Interaction and communication4 items
Display7-inch colour touchscreen
Activation methodsQR code, VIN and card activation
Communication interfaceCAN
BMS auxiliary supply12 V / 24 V compatible
Electrical performance4 items
Charging voltage range150–1000 VDC
Charging current range0–250 A / 0–300 A per connector
Current regulation accuracy≤±1%
Voltage regulation accuracy≤±0.5%
Protection10 items
Input overvoltage protectionNo output after protection; recoverable
Input undervoltage protectionNo output after protection; recoverable
Input overcurrent protectionNo output after protection; manual reset required
Input phase-loss protectionNo output after protection; recoverable
Output overvoltage protectionNo output after protection; recoverable
Communication fault protectionNo output after protection; recoverable
Short-circuit protectionNo output after protection; manual reset required
Emergency-stop protectionNo output after protection; manual reset required
Overtemperature protectionNo output after protection; recoverable
Lightning protectionNo output after protection; manual reset required
Environmental conditions4 items
Operating temperature−25 to 50 °C (normal operation)
Relative humidity0–95% (no frost)
Altitude≤2000 m
Storage temperature−45 to 75 °C
Liquid-cooled terminal600 kW
Configuration and installation7 items
ModelF/ZD600
Power options600 kW
ConnectorsDual connector
Charging cable length5 m
InstallationFloor mounting; power cabinet and terminals installed separately
Enclosure materialGalvanized enclosure
Dimensions1850 × 960 × 450 mm (source order; length / width / height order to be confirmed)
Interaction and communication4 items
Display7-inch colour touchscreen
Activation methodsQR code, VIN and card activation
Communication interfaceCAN
BMS auxiliary supply12 V / 24 V compatible
Electrical performance4 items
Charging voltage range150–1000 VDC
Charging current range0–600 A per connector
Current regulation accuracy≤±1%
Voltage regulation accuracy≤±0.5%
Protection10 items
Input overvoltage protectionNo output after protection; recoverable
Input undervoltage protectionNo output after protection; recoverable
Input overcurrent protectionNo output after protection; manual reset required
Input phase-loss protectionNo output after protection; recoverable
Output overvoltage protectionNo output after protection; recoverable
Communication fault protectionNo output after protection; recoverable
Short-circuit protectionNo output after protection; manual reset required
Emergency-stop protectionNo output after protection; manual reset required
Overtemperature protectionNo output after protection; recoverable
Lightning protectionNo output after protection; manual reset required
Environmental conditions4 items
Operating temperature−25 to 50 °C (normal operation)
Relative humidity0–95% (no frost)
Altitude≤2000 m
Storage temperature−45 to 75 °C

Dimensions retain the order in the technical specification; confirm axis order when selecting the equipment. Connector standards, IP ratings and project-specific requirements require separate confirmation.

These specifications describe the listed configurations. Confirm destination-market mains supply, connector requirements, platform integration and required certification for each export order.

Discuss your export and customization brief.

Share your destination market, quantity, branding and technical requirements.