Explore product views and specifications, then discuss export supply and OEM / ODM configuration.
01 / 05
Cabinet · Angled view
Drag to rotate · Buttons to zoomPreparing 3D…
Enclosure illustration
An enclosure illustration based on product images. Dimensions and construction are subject to the agreed specification.
Split charging system
720 kW~1 MW+
Cabinet · Standard / liquid-cooled terminals
F6 / F19 cabinets cover 720 kW~1 MW+, paired with air-cooled or liquid-cooled terminals. Review the listed configuration ratings, then discuss export configuration and customization.
Air-cooled terminal current is 0–250 A / 0–300 A per connector; the liquid-cooled terminal supports 0–600 A per connector. Terminal power and per-connector current are specified separately.
03
Separate cabinet and terminals
The cabinet provides an internal service-display interface. Terminals have a 7-inch colour touchscreen with QR, VIN and card activation.
Cabinet total power, terminal rating and per-connector current are selected separately
Images illustrate enclosure options. Model, dimensions, connector and performance specifications are confirmed for the agreed configuration.
TECHNICAL SPECIFICATIONS
Technical specifications
View the configuration, then expand performance, protection and operating conditions.
Cabinet ratings are total cabinet power. Terminal output ratings are not per-connector ratings. Actual output depends on cabinet allocation, vehicle demand and system configuration.
F6 · Power cabinet720 / 800 / 960 kW
Configuration and installation6 items
Model
F6
Power options
720 / 800 / 960 kW
Connectors
Configured for the project (customized within the specified limits)
Installation
Floor mounting; cabinet and terminals installed separately
Enclosure material
Galvanized enclosure
Dimensions
1960 × 1700 × 1200 mm (source order; length / width / height order to be confirmed)
Interaction and communication3 items
Display
No external display; internal commissioning display interface provided
Communication interface
CAN
BMS auxiliary supply
12 V / 24 V compatible
Electrical performance9 items
Input voltage
AC 380 V ±15%
Supply frequency
50 Hz ±5 (tolerance unit to be confirmed)
Charging voltage range
150–1000 VDC
Charging current range
250 A / 300 A / 600 A options
Input power factor
≥0.99
Charging efficiency
≥96.5% (peak charging efficiency)
Harmonic current
≤5%
Current regulation accuracy
≤±1%
Voltage regulation accuracy
≤±0.5%
Protection10 items
Input overvoltage protection
No output after protection; recoverable
Input undervoltage protection
No output after protection; recoverable
Input overcurrent protection
No output after protection; manual reset required
Input phase-loss protection
No output after protection; recoverable
Output overvoltage protection
No output after protection; recoverable
Communication fault protection
No output after protection; recoverable
Short-circuit protection
No output after protection; manual reset required
Emergency-stop protection
No output after protection; manual reset required
Overtemperature protection
No output after protection; recoverable
Lightning protection
No output after protection; manual reset required
Environmental conditions4 items
Operating temperature
−25 to 50 °C (normal operation)
Relative humidity
0–95% (no frost)
Altitude
≤2000 m
Storage temperature
−45 to 75 °C
F19 · Power cabinet1280 / 1600 / 1920 kW
Configuration and installation6 items
Model
F19
Power options
1280 / 1600 / 1920 kW
Connectors
Configured for the project (customized within the specified limits)
Installation
Floor mounting; cabinet and terminals installed separately
Enclosure material
Galvanized enclosure
Dimensions
1960 × 2100 × 1200 mm (source order; length / width / height order to be confirmed)
Interaction and communication3 items
Display
No external display; internal commissioning display interface provided
Communication interface
CAN
BMS auxiliary supply
12 V / 24 V compatible
Electrical performance9 items
Input voltage
AC 380 V ±15%
Supply frequency
50 Hz ±5 (tolerance unit to be confirmed)
Charging voltage range
150–1000 VDC
Charging current range
250 A / 300 A / 600 A options
Input power factor
≥0.99
Charging efficiency
≥96.5% (peak charging efficiency)
Harmonic current
≤5%
Current regulation accuracy
≤±1%
Voltage regulation accuracy
≤±0.5%
Protection10 items
Input overvoltage protection
No output after protection; recoverable
Input undervoltage protection
No output after protection; recoverable
Input overcurrent protection
No output after protection; manual reset required
Input phase-loss protection
No output after protection; recoverable
Output overvoltage protection
No output after protection; recoverable
Communication fault protection
No output after protection; recoverable
Short-circuit protection
No output after protection; manual reset required
Emergency-stop protection
No output after protection; manual reset required
Overtemperature protection
No output after protection; recoverable
Lightning protection
No output after protection; manual reset required
Environmental conditions4 items
Operating temperature
−25 to 50 °C (normal operation)
Relative humidity
0–95% (no frost)
Altitude
≤2000 m
Storage temperature
−45 to 75 °C
Air-cooled terminal250 / 300 kW
Configuration and installation7 items
Model
F/ZD250 / F/ZD300
Power options
250 / 300 kW
Connectors
Dual connector
Charging cable length
5 m
Installation
Floor mounting; power cabinet and terminals installed separately
Enclosure material
Galvanized enclosure
Dimensions
1431 × 616 × 325 mm (source order; length / width / height order to be confirmed)
Interaction and communication4 items
Display
7-inch colour touchscreen
Activation methods
QR code, VIN and card activation
Communication interface
CAN
BMS auxiliary supply
12 V / 24 V compatible
Electrical performance4 items
Charging voltage range
150–1000 VDC
Charging current range
0–250 A / 0–300 A per connector
Current regulation accuracy
≤±1%
Voltage regulation accuracy
≤±0.5%
Protection10 items
Input overvoltage protection
No output after protection; recoverable
Input undervoltage protection
No output after protection; recoverable
Input overcurrent protection
No output after protection; manual reset required
Input phase-loss protection
No output after protection; recoverable
Output overvoltage protection
No output after protection; recoverable
Communication fault protection
No output after protection; recoverable
Short-circuit protection
No output after protection; manual reset required
Emergency-stop protection
No output after protection; manual reset required
Overtemperature protection
No output after protection; recoverable
Lightning protection
No output after protection; manual reset required
Environmental conditions4 items
Operating temperature
−25 to 50 °C (normal operation)
Relative humidity
0–95% (no frost)
Altitude
≤2000 m
Storage temperature
−45 to 75 °C
Liquid-cooled terminal600 kW
Configuration and installation7 items
Model
F/ZD600
Power options
600 kW
Connectors
Dual connector
Charging cable length
5 m
Installation
Floor mounting; power cabinet and terminals installed separately
Enclosure material
Galvanized enclosure
Dimensions
1850 × 960 × 450 mm (source order; length / width / height order to be confirmed)
Interaction and communication4 items
Display
7-inch colour touchscreen
Activation methods
QR code, VIN and card activation
Communication interface
CAN
BMS auxiliary supply
12 V / 24 V compatible
Electrical performance4 items
Charging voltage range
150–1000 VDC
Charging current range
0–600 A per connector
Current regulation accuracy
≤±1%
Voltage regulation accuracy
≤±0.5%
Protection10 items
Input overvoltage protection
No output after protection; recoverable
Input undervoltage protection
No output after protection; recoverable
Input overcurrent protection
No output after protection; manual reset required
Input phase-loss protection
No output after protection; recoverable
Output overvoltage protection
No output after protection; recoverable
Communication fault protection
No output after protection; recoverable
Short-circuit protection
No output after protection; manual reset required
Emergency-stop protection
No output after protection; manual reset required
Overtemperature protection
No output after protection; recoverable
Lightning protection
No output after protection; manual reset required
Environmental conditions4 items
Operating temperature
−25 to 50 °C (normal operation)
Relative humidity
0–95% (no frost)
Altitude
≤2000 m
Storage temperature
−45 to 75 °C
Dimensions retain the order in the technical specification; confirm axis order when selecting the equipment. Connector standards, IP ratings and project-specific requirements require separate confirmation.
These specifications describe the listed configurations. Confirm destination-market mains supply, connector requirements, platform integration and required certification for each export order.
Discuss your export and customization brief.
Share your destination market, quantity, branding and technical requirements.