Charging and interaction
Dual connector · 7 m · 7-inch colour touchscreen
PRODUCT / DC CHARGING
Explore product views and specifications, then discuss export supply and OEM / ODM configuration.
01 / 06Angled view
An enclosure illustration based on product images. Dimensions and construction are subject to the agreed specification.
High-power series · Multiple views
240 / 320 / 400 / 480 kW options with dual connectors and 7 m cables. Per-connector current is 0–300 A. Define the configuration against vehicle requirements, site capacity and the destination market.
FEATURES / CONFIGURATION
Dual connector · 7 m · 7-inch colour touchscreen
150–1000 V DC. Review the BMS auxiliary supply and current configuration in the technical specifications.
Floor mounting. Normal operating temperature: −25 to 50°C; altitude up to 2000 m.
SELECTION / CONFIGURATION
Images illustrate enclosure options. Model, dimensions, connector and performance specifications are confirmed for the agreed configuration.
TECHNICAL SPECIFICATIONS
View the configuration, then expand performance, protection and operating conditions.
| Model | LDXDC240KW-2 / LDXDC320KW-2 / LDXDC400KW-2 / LDXDC480KW-2 |
|---|---|
| Power options | 240 / 320 / 400 / 480 kW |
| Connectors | Dual connector |
| Charging cable length | 7 m |
| Installation | Floor mounting |
| Enclosure material | Galvanized enclosure |
| Dimensions | 1900 × 850 × 810 mm (source order; length / width / height order to be confirmed) |
| Display | 7-inch colour touchscreen |
|---|---|
| Activation methods | QR code, VIN, card and password activation |
| Communication interface | CAN |
| BMS auxiliary supply | 12 V / 24 V compatible |
| Input voltage | AC 380 V ±15% |
|---|---|
| Supply frequency | 50 Hz ±5 (tolerance unit to be confirmed) |
| Charging voltage range | 150–1000 VDC |
| Charging current range | 0–300 A per connector |
| Input power factor | ≥0.99 |
| Charging efficiency | ≥96.5% (peak charging efficiency) |
| Harmonic current | ≤5% |
| Current regulation accuracy | ≤±1% |
| Voltage regulation accuracy | ≤±0.5% |
| Input overvoltage protection | No output after protection; recoverable |
|---|---|
| Input undervoltage protection | No output after protection; recoverable |
| Input overcurrent protection | No output after protection; manual reset required |
| Input phase-loss protection | No output after protection; recoverable |
| Output overvoltage protection | No output after protection; recoverable |
| Communication fault protection | No output after protection; recoverable |
| Short-circuit protection | No output after protection; manual reset required |
| Emergency-stop protection | No output after protection; manual reset required |
| Overtemperature protection | No output after protection; recoverable |
| Lightning protection | No output after protection; manual reset required |
| Operating temperature | −25 to 50 °C (normal operation) |
|---|---|
| Relative humidity | 0–95% (no frost) |
| Altitude | ≤2000 m |
| Storage temperature | −45 to 75 °C |
Dimensions retain the order in the technical specification; confirm axis order when selecting the equipment. Connector standards, IP ratings and project-specific requirements require separate confirmation.
These specifications describe the listed configurations. Confirm destination-market mains supply, connector requirements, platform integration and required certification for each export order.
Share your destination market, quantity, branding and technical requirements.